Dust extraction fan bearing fault detected through vibration monitoring
Diagnosed issue
In June 2026, Sonora detected multiple strong harmonics around 60 Hz and increasing RMS on a Cognor dust extraction fan. The initial vibration pattern suggested possible debris accumulation, which the customer reported shortly after the notification.
Despite this finding, abnormal vibration persisted. Sonora continued monitoring the equipment, identifying increasing RMS, shifting centroid, and stronger harmonics. Further inspection of the fan, shaft, and bearings was recommended to investigate possible wear or imbalance.
Following an equipment shutdown, RMS levels decreased by approximately 2-3 times, although elevated harmonics remained. Cognor later confirmed that the support bearing located directly after the motor had been replaced, validating the defect as a true positive.
Results
Sonora detected abnormal vibration and tracked its development over several months, supporting further mechanical investigation. Cognor confirmed replacement of the support bearing, while continued monitoring documented significant changes in vibration levels. The customer’s Maintenance Manager also expressed satisfaction with the system and its contribution to equipment monitoring.